Pendent Fire Sprinkler Heads
Pendent Fire Sprinkler Heads

Pendent Fire Sprinkler Heads

MOQ : 1 Piece

Pendent Fire Sprinkler Heads Specification

  • Coverage Area
  • 12-21 sq. m per head (depending on ceiling height and spacing)
  • Installation Type
  • Ceiling mount (pendent)
  • Shape
  • Pendent head (downward spray deflector)
  • Features
  • Corrosion-resistant, fast-response, tamper-resistant shield
  • Working Temperature
  • Glass bulb options available - typically 57C, 68C, and 79C
  • Connectivity Type
  • Physical connection to water pipe network
  • Fire Extinguisher Type
  • Water assisted (sprinkler system type)
  • Mounting Type
  • Ceiling mounted, threaded connection
  • Technology
  • Wet and Dry Pendent Sprinkler Technology
  • Fire Class
  • Class A, B, C (general combustible, flammable liquids, and electrical fires)
  • Coating Type
  • Chrome-plated or corrosion-resistant finish
  • Voltage
  • N/A (mechanically actuated, no electrical power required)
  • Energy Efficiency Rating
  • Not applicable (mechanical activation)
  • Operating Pressure
  • 0.5 to 1.2 MPa
  • Control Type
  • Automatic (heat-activated bulb mechanism)
  • Application
  • Fire suppression in commercial, industrial, and residential buildings
  • Max Flow Rate
  • Varies (typically 80-115 L/min depending on system design)
  • Capacity
  • N/A (works with central water supply)
  • Diameter
  • 15 mm (1/2 inch) standard thread size
  • Pressure
  • Standard 1.2-1.4 bar (operating range varies by system)
  • Material
  • Brass body with stainless steel components, heat-sensitive glass bulb
  • Finish
  • Polished Brass/Chrome/Custom finish
  • Thread Specification
  • 1/2" BSPT/NPT (optional: 3/4" available)
  • Minimum Distance from Ceiling
  • 25 mm (typical installation requirement)
  • Bulb Size
  • 5 mm bulb (industry standard)
  • Maximum Ambient Temperature
  • Up to 107C (depending on bulb rating)
  • Response Time Index (RTI)
  • Standard and quick response available
  • Minimum Operating Temperature
  • 54C
  • Spray Pattern
  • Uniform, circular water distribution
 

Pendent Fire Sprinkler Heads Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 500 Pieces Per Month
  • Delivery Time
  • 2-5 Days
  • Main Domestic Market
  • All India
 

About Pendent Fire Sprinkler Heads



Discover Triumphant fire safety with our Majestic Pendent Fire Sprinkler Heads, crafted from premium brass and stainless steel components. Featuring heat-sensitive glass bulbs in standard and quick response options, these sprinklers provide a uniform, circular water distribution for optimal coverage. Enjoy reduced rates and best price promotions for commercial, industrial, and residential installations across India. With corrosion-resistant construction and tamper-resistant shields, these ceiling-mounted heads deliver terrific reliability and longevity. Choose from polished brass, chrome, or custom finishes to suit your requirements. Secure your premises with this superior, automatic fire suppression solution today.

Surface Suitability & Versatile Application for Safety

Pendent Fire Sprinkler Heads are designed for ceiling installation in commercial, industrial, and residential environments. Their uniform spray pattern ensures reliable coverage for surfaces prone to fire risks, such as office ceilings or factory floors. These heads are perfect for applications demanding consistent safety, including warehouses, retail spaces, data centers, and homes. Key features include heat-activated response, corrosion resistance, and a tamper-resistant design, making them ideal for safeguarding diverse environments from potential fire hazards.


Certifications, Sample Policy & Packaging Excellence

All Pendent Fire Sprinkler Heads come with certification support documentation available upon Quotation request, ensuring compliance with safety standards. Sample policies can be discussed to accommodate specific project requirements. For shipment, we offer sturdy packaging that preserves product integrity, facilitating secure delivery across India. Request your lowest price with bulk purchase orders or customized requirements. Count on our reliable distribution and packaging process for efficient supply and peace of mind.


FAQ's of Pendent Fire Sprinkler Heads:


Q: How does the heat-sensitive glass bulb in the Pendent Fire Sprinkler Heads operate?

A: The glass bulb contains a liquid that expands when exposed to heat. Once the temperature reaches a preset threshold, the bulb bursts and the sprinkler activates, releasing water to suppress fires automatically.

Q: What are the main benefits of using these sprinkler heads in my building?

A: These sprinkler heads provide rapid, automatic fire response, uniform water coverage, corrosion resistance, and tamper protection, making them essential for reliable fire suppression in a variety of commercial, industrial, and residential settings.

Q: Where can Pendent Fire Sprinkler Heads be installed?

A: They are suitable for ceiling installation in any environment requiring fire protection-office buildings, factories, warehouses, retail stores, data centers, and residential complexes.

Q: What is the process to request a quotation and sample for this product?

A: You can contact our sales team to receive a detailed quotation and discuss sample policies. We'll guide you through customization, bulk pricing, and delivery schedules tailored to your needs.

Q: When should I choose standard or quick response sprinkler heads?

A: Choose quick response heads for high-occupancy areas requiring faster fire control, such as offices and schools. Standard response heads are ideal for industrial or storage areas with less immediate evacuation concerns.