16 PN Sluice Valve
16 PN Sluice Valve

16 PN Sluice Valve

MOQ : 10 Pieces

16 PN Sluice Valve Specification

  • Working Temperature
  • -10C to +80C (approx)
  • Technology
  • Rising spindle, resilient-seated sluice valve
  • Coating Type
  • Epoxy Powder Coated or Liquid Painted (external & internal protection)
  • Operating Pressure
  • PN 16 (16 bar / 232 psi)
  • Coverage Area
  • Pipeline Section where installed
  • Features
  • Corrosion resistant, robust design, long operational life, easy maintenance, bubble-tight shut-off
  • Fire Class
  • Not Rated for Fire Extinguishing-General Isolation Valve
  • Connectivity Type
  • Flanged Ends
  • Control Type
  • Manual (Handwheel Operated)
  • Shape
  • Round Body with Rising Spindle
  • Installation Type
  • Horizontal/Vertical Pipe Mounting
  • Mounting Type
  • Flanged Mounting
  • Application
  • Water supply, sewage, irrigation, and fire fighting systems
  • Max Flow Rate
  • Dependent on line pressure and application, typically high for this size
  • Capacity
  • Standard to Nominal Bore Size
  • Diameter
  • 16 inches (DN400)
  • Pressure
  • PN 16 (Max 16 bar / 232 psi)
  • Spindle Material
  • Stainless Steel or Bronze
  • End Connection
  • Flanged Drilled to ANSI/BS/DIN standards
  • Operation Method
  • Handwheel (optionally with gear or actuator for large sizes)
  • Bonnet Type
  • Bolted Bonnet
  • Suitable Media
  • Water, Neutral Liquids
  • Test Pressure
  • 1.5x working pressure (hydrostatically tested)
  • Leakage Class
  • Class A (Bubble Tight)
  • Material
  • Ductile Iron/ Cast Iron Body with Bronze/Brass Trim
  • Sealing Method
  • Resilient Seated (Rubber/EPDM Gasket)
 
 

About 16 PN Sluice Valve



Discover the perfect solution for robust pipeline control with our 16 PN Sluice Valve. Crafted from kingly Ductile Iron or Cast Iron with valuable Bronze/Brass trims, this valve delivers cost-effective and reliable performance across in-demand water supply, sewage, irrigation, and fire fighting systems. The bolted bonnet, stainless steel spindle, and resilient-seated design ensure a bubble-tight, leak-proof seal for maximum efficiency. Corrosion resistant and easy to maintain, its sturdy construction provides a long operational life. Find the ideal partner for horizontal or vertical installations, designed to meet ANSI/BS/DIN standards.

Precision and Durability in Every Application

The 16 PN Sluice Valve excels in water supply, sewage, and fire-fighting networks. Install on horizontal or vertical piping where precise manual flow control and kingly reliability are needed. Simply operate with the robust handwheel for smooth on/off function. Its resilient-seated design guarantees a bubble-tight shut-off, and top-tier corrosion resistance extends operational life. Valuable features like easy maintenance and compatibility with both ANSI, BS, and DIN flanged connections ensure optimal performance in any setting.


Payment, Delivery, and Terms Made Simple

Secure your order with a valid Purchase Order for quick processing. Upon approval, timely Goods Transport is arranged from our India FOB port, catering to regional and international clients. Standard delivery time is prompt, depending on stock and quantity-transportation logistics are managed for your convenience. Each shipment is handled with care, guaranteeing safe and efficient delivery to your site, fulfilling both urgent and routine demands for valuable pipeline solutions.


FAQ's of 16 PN Sluice Valve:


Q: How should the 16 PN Sluice Valve be installed for optimal performance?

A: The 16 PN Sluice Valve can be mounted on horizontal or vertical pipelines using its flanged ends, ensuring it aligns with the flow direction markings on the valve body. Proper installation guarantees reliable operation and a long service life.

Q: What applications is this sluice valve suitable for?

A: This valve is ideal for water supply, irrigation, sewage, and fire fighting systems, offering bubble-tight shut-off for general flow isolation in industrial and municipal pipelines.

Q: When can I expect delivery after placing a purchase order?

A: Delivery of the 16 PN Sluice Valve typically depends on current inventory and order volume but is processed promptly following order confirmation. Goods are transported from our India FOB port in line with agreed timelines.

Q: What materials enhance the valve's durability?

A: The valve features a Ductile Iron or Cast Iron body with Bronze or Brass trim and a corrosion-resistant stainless steel or bronze spindle, all protected by epoxy powder coating or liquid painting for maximized service life.

Q: How does the manual operation benefit end users?

A: The handwheel-operated control allows precise flow regulation. For larger sizes, optional gear or actuator operation adds convenience, making the valve perfect for high-demand and kingly pipeline applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Fighting Accessories Category

SS Hydrant Shank Reducer

SS Hydrant Shank Reducer

Minimum Order Quantity : 1 Piece

Mounting Type : Coupling Mounted

Diameter : 63 mm (commonly), custom sizes available

Installation Type : Inline/Onsite connection

Shape : Round Shank with Reducer Flange

Connectivity Type : Shank/Threaded Coupling

Modular And Fire Ball

Modular And Fire Ball

Minimum Order Quantity : 10 Pieces

Mounting Type : Ceiling Mounted, Wall Mounted, Floor Stand

Diameter : 150 mm to 200 mm (approx)

Installation Type : Ceiling Mount, Wall Mount, or Floor Stand

Shape : Spherical (Ball), Cylindrical (Modular)

Connectivity Type : Standalone, No External Connection Required

Ball Type NRV

Ball Type NRV

Minimum Order Quantity : 10 Pieces

Mounting Type : Pipe mounted

Diameter : 50 mm to 300 mm

Installation Type : Horizontal or Vertical

Shape : YPattern

Connectivity Type : Flanged end connection

Foot Valve Flanged

Foot Valve Flanged

Minimum Order Quantity : 10 Pieces

Mounting Type : Pipe/flange mounting

Diameter : Available in various sizes, typically from 50 mm to 300 mm

Installation Type : Horizontal or vertical installation at pump inlet

Shape : Angled body with domed strainer

Connectivity Type : Flanged End Connection



Back to top